80 Ton Water Cooled Explosion Proof Screw Chiller
  • 80 Ton Water Cooled Explosion Proof Screw Chiller

80 Ton Water Cooled Explosion Proof Screw Chiller

This 80 Ton /300KW water cooled explosion-proof screw chiller is a particularly chiller unit that installed in harsh or explosive industrial applications,such as chemical plants,petrochemical plants and laboratories and so on.

Chiller Model:          TW-300WSH

Cooling Capacity:    300KW(258000 kcal/h)  

Refrigerant:             R22/R407c/R134A

Power Supply:         380V/50HZ /3PH (Standard)
                                208-480V/60HZ/3PH(Customized)

Compressor Brand: Hanbell/Bitzer Screw Compressor

Evaporator Type:   Shell and Tube

Condenser Type:   Shell and Tube

    Content
    ▷1.
    What is An Explosion-Proof Chiller?
    ▷2.
    Why Explosion-Proof Chillers Are So Important
    ▷3.
    How Does an Explosion-Proof Chiller Work?
    ▷4.
    Types of Explosion-Proof Chillers
    ▷5.
    What Are The Main Components of Explosion-proff Chillers?

           5.1 Compressor

           5.2 Evaporator

           5.3 Water Pump

           5.4 Condenser

           5.5 Electric Box
    ▷6.
    What are the Applications of an Explosion Proof Chiller?
    ▷7.
    Contact Us to Learn More About Our Explosion-Proof Chillers


    1.What is An Explosion-Proof Chiller?

    An Explosion Proof Chiller is also called hazardous process chiller, which is a particularly chiller unit that installed in harsh or explosive industrial applications,so it is with reinforced design to protect the chiller’s components from ambient flammable materials that could cause an explosion.

    The explosion proof chiller must be sealed wiring to protect the air from stray sparks that could ignite any vapors or flammable gases. Chillers utilized within hazardous environments must have adequate physical protection and special safety features built-in to prevent damage to sensitive components.Adhering to these guidelines and fulfilling our customers’ needs require us to custom-design many of our explosion-proof chillers.


    Water Cooled Explosion Proof Screw Chiller 

    2.Why Explosion-Proof Chillers Are So Important

    In order to protect the safety of employees and facilities, reducing the likelihood of explosions becomes the primary goal of any business owner. Some work-sites are more dangerous than others. Reduce the risk that sparks from the chiller could ignite explosive or flammable materials, which is why explosion-proof chiller is a safety requirement in many industries. Although the price of all explosion-proof equipment is high, the cost is far less than the loss of life caused by industrial accidents due to the use of the wrong machinery.
    In addition to safety concerns, explosion-proof chillers are required by law in many locations where with combustible materials in the air. In addition to the danger of igniting flammable substances, non-compliance could result in huge emissions.

    3.How Does an Explosion-Proof Chiller Work?

    There are many types of explosion-proof chillers, and how each one works depends on the components used. For example, there are screw and scroll compressors, air-cooled and water-cooled condensers. The components of the chiller system are not explosion-proof. The design of the entire system. But these components determine the ultimate efficiency of the chiller and the temperatures it can reach. Use this information when choosing a chiller for your workplace. 
    Most chillers operate in the same way, in short, by continuously flowing refrigerant to the cold end of the evaporator at the desired temperature. The chiller then pumps the cooled fluid through the process to dissipate heat from the equipment and funnel it back to the return side. The range of chiller we choose is -60 F to 30 F. If you have any special requirements for the cooling of chiller, please contact us .
    The refrigerant starts the process in a mixture of liquid and gas. The gas and liquid enter the evaporator, where the heat converts the refrigerant into a low-pressure gas. This gas enters a compressor, which compresses the gas to a high pressure state using one of several methods. This gas moves to the condenser, which can cool the refrigerant with water or air. In a condenser, the coolant releases heat and condenses into a liquid. When the liquid is at high pressure as it passes through the expansion valve, the expansion valve controls how much cooled refrigerant enters the evaporator and starts the cycle again.


    Air-Cooled Explosion Proof Chiller Installation


    Water-Cooled Explosion Proof Chiller Installation

    4.Types of Explosion-Proof Chillers

    We offer explosion proof chillers from 1/2 ton to 200 tons to cool all sizes in your application. Learn more about our explosion proof chiller.

    Scroll Explosion Proof Chiller 
    Our single-, dual-, and multi-circuit scroll explosion proof chillers are available with scroll compressor, an industry-leading and long-lasting solution.

         ▪ Air- and Water-cooled Scroll

         ▪ 1 - 60 hp (1KW- 200KW)

         ▪ Single-, dual-, or multi-circuit(Three or Four )

         ▪ Panasonic or Danfoss scroll Compressor
       

                     
    20HP Air-Cooled Scroll Explosion Proof Chiller                              30HP Water-Cooled Scroll Explosion Proof Chiller       

    Screw Explosion Proof Chiller 
    Our Single or Dual-circuit screw explosion proof chillers feature Hanbell or Bizter screw compressors for long-lasting performance and reliability.

         ▪ Air- and Water-cooled

         ▪ 60 - 300 hp (200KW-1500KW)

         ▪ Single or Dual-circuit 
          
     

    5.What Are The Main Components of Explosion-proff Chillers?

    5.1 Compressor
    The compressor is the key mover in explosion proof chiller because it produces pressure variations to stir the refrigerant around.
    From 1/2HP(1/2 Ton) to 60HP(5oTon) brewery chiller , which is with Panasonic or Danfoss brand Scroll compressor ,
    Above 60HP(50 Ton) explosion proof chiller , which is with Hanbell or Bitzer brand Screw compressor ,
    These brand compressors are with high refrigeration efficiency,low noise ,energy saving,environmental protection and durability,safety and stability. 

    Panasonic Compressor


    Danfoss Compressor

    5.2 Evaporator
    The evaporator is a crucial component of explosion proof chiller, as it is responsible for extracting heat from the liquid being cooled,it is located between the compressor and the expansion valve. There are three types of evaporators : coil in water tank evaporator , shell and tube evaporator, 304SS stainless steel plate type evaporator. 

    Coil in SS Water Tank Evaporator


     SS Plate Type+ Water Tank Evaporator



    Shell and Tube Evaporator

    5.3 Water Pump
    The water pump for explosion proof chiller is explosion-proof .


    Explosion Proof Water Pump


    5.4 Condenser

    The condenser for air cooled explosion chiller is equipped with efficient cross-seam fins and female threaded copper tubes for high heat exchange efficiency and good stability. The fan on the top of explosion proof chiller is also explosion proof .

     
    Aluminum fin+fan Condenser for explosion proof chiller

    The condenser for water-cooled explosion proof chiller is shell and tube ,with the internal copper tubes employing an outer thread embossing process.This design effectively enhances the heat exchange efficiency between the refrigerant and water during the process. Compared to traditional smooth copper tubes, the outer thread embossing process increases the surface area of the copper tubes, thereby expanding the contact area for heat exchange and improving the thermal conductivity of the condenser. This optimization design allows the condenser of the water-cooled chiller to transfer heat from the refrigerant to the water more rapidly and consistently, enabling the water to carry away the heat.


    Shell and tube Condenser for water-cooled explsoion proof chiller

    5.5 Electric Box
     The electric box for chiller is also explosion proof .


    Explosion Proof Electric Box 

    6.What are the Applications of an Explosion Proof Chiller?
    Explosion-proof chillers have a variety of applications where cooling and protection from any type of explosion is required, including as below :

    Chemical Plants
    Chemical factories may generate or store potentially flammable substances. Even in storage spaces, the facility will need explosion-proof equipment. 

    Petrochemical Plants
    To distinguish a petrochemical plant from an oil refinery, the former manufactures substances from petroleum while the latter refines crude oil. Both handle hazardous materials. The popularity of many petrochemicals, such as gasoline, is partly due to their flammability. The same properties also put petrochemical plants at risk of fire.

    Cooling Flammable Liquids
    Flammable liquids often emit hazardous vapors. These vapors make explosion-proof chillers and other equipment in the space required. If the fluid remains sealed, the area will only require Class I, Division 2 approved equipment.

    Refineries
    Petrochemical refinement requires extreme caution with all materials used. Flammable gases produced in refineries require Class 1 explosion-proof chillers.

    Sample or Process Analyzers
    Using sample or process analyzers, workers can identify the chemical makeup of various substances. Explosion protection in the sample analysis area saves lives as the components are unknown and potentially harmful elements.

    Granaries
    Flour is very flammable. Ask anyone who lives near a granary and has heard stories of the explosions. The fine dust in the air only needs a small spark to detonate. This is why silos and grain bins require explosion proof equipment.

    Laboratories
    Ventilation in laboratories is critical to the safety and health of workers. Fire safety and explosion protection are also important. Anywhere volatile, flammable vapors or gases are present, special electrical components are required to prevent stray sparks that could ignite.

    7.Contact Us to Learn More About Our Explosion-Proof Chillers

    Don’t delay in making the best decision for your manufacturing business and your future by increasing your production capabilities with explosion proof chiller. Contact us today for more information on a explosion-proof chiller.
    Our probessional team will help you with any questions you have on our explosion proof chiller units. We look forward to hearing from you!


                 100 Ton Water Cooled Explosion Proof Screw 

               Chiller 
    Technical Specifications MODEL:TW-350WSH

    Model

    TW-300WSH

    nominal cooling capacity

    KW

    300

    Ton

     85.30

    Kca/h

    258000

    Chilled Water Temperature Range

    5~35℃

    Max power consumption

    kw

    65

    Full load

    Amp

    109

    power source

     

    3PH - 380V - 50HZ (Standard)

    3PH - 220-480V - 60HZ 

    refrigerant

    type

     

    R407c

    Charge volume

    kg

    50

    control

     

    Electric thermal expansion valve

    compressor

    type

     

    Semi-hermetic screw

    Power

    KW

    65

    Start mode

     

    Y-△

    Capacity control

     

    0-25-50-75-100%

    condenser

    type

     

       Water cooled shell and tube type condenser

    Cooling tower water flow rate 

    m3/h

    62.8

    Pressure

    Kpa

    43

    inlet and outlet connection


    Inch

    4

    evaporator

    type

     

     Dry shell and tube type evaporator

    Chilled water flow rate

    m3/h

    51.6

    Pressure

    KPa

    42

    inlet and outlet connection

    Inch

                                4

    safety devices

    Over load relay for compressor ,over-current protection,high and low pressure protection,over-temperature protection,traffic protection, three-phase error protection relay, coolant level switch, flow switch

    dimension

    mm

    2800*950*1950

    Machinery weight

    kg

    1900

    Running Weight

    kg

    2200

     

    1 . Testing results under above conditions: Inlet/outlet chilled water temperature 12℃/7℃, condensing temperature 45℃.

    2. The above parameters will be updated continuously. If you have special request, please send your technical requirements before placing an order.
    1.How does a chiller system work?
    Chiller has two circulation,one is process water circulation,the other is refrigerant gas circulation.Heat picked up from the process.Heat transfers to refrigerant circulation.Heat is remove to air or water.

    2.How to calculate right cooling capacity for chillers?
    One of the most frequently ask about how we can know the cooling capacity for chillers. Let’s see the below formula.
    Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-T2)/0.86
    Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)
    Oversize the chiller by 20% Ideal Size in KW = KW x 1.2
    Noted : T1:Incoming Water Temperature (℃)      T2:Required Chilled Water Temperature(℃)    
        
    For example, what size of chiller is required to cool 5m³ water from 25°c to 15 °c in 1 hour?
    Temperature Differential = 25℃-15℃=10℃
    Water Flow Rate = 5 m³/hour
    Cooling Capacity in KW = 5 x 10 ÷ 0.86 = 58,14 KW
    Oversize the chiller = 58.14 x 1.2 = 69.76 KW
    69.96kw cooling capacity for chiller is required.

    3.Types of chiller system?
    There are two types of chiller :Air Cooled Screw Chiller and Water Cooled Screw Chiller.
    Water cooled chiller needs a separated water cooling tower and water cooling pump ,if you don‘t have exsiting water cooling tower,we suggest you use air cooled chiller; But if your ambiemt temperature is very high above 55℃ ,we suggest you use water cooled chiller , as it is easier to dissipate heat for water cooled chiller with water cooling tower.

    4.Cooling capacity unit conversion?

       1 KW=860 kcal/h ; 

       1 TON=3.517 KW; 

       1 KW=3412 Btu/h;

    5.This chiller could do heat recovery?
    Yes,please kindly send us the temp and water volume per hour.

    6.Chiller maintenance?
    Step 1: Keep Tubes Clean
    Step 2: Ensure a Leak-free Unit
    Step 3: Sustain Proper Water Treatment(prevent scale, corrosion)
    Step 4: Analyze Oil and Refrigeran
    Please submit your basic information, we will contact you as soon as possible!

    *

    *

    File Name : Format: Size: Download:

Related products

  • Tel:+86 15320636029
  • Add:Fengxiang,Humen Town,Dongguan,China,
About Us77
Company Profile
Company culture
Factory Tour
Honor
Product
Industrial Chiller
Screw Chiller
Glycol Chiller
Explosion-Proof Chiller
Portable Chiller
Stationary Chiller
REQUEST QUOTE

Name

Email

Phone

Message

©2023 GuangDong TongWei Refrigeration Machinery Co., Ltd.   All rights reserved  
Web Design—Tiandixin