• +86 15320636029
  • info@cooling-chiller.com
REQUEST A QUOTE
Product

Product

Contact

You are here:Home >> Product >> Industrial Chiller... >> Industrial Air Cooled Chil...

Industrial Air Cooled Chiller

6 Ton 8HP Industrial Chiller System For Vacuum Coating Machine
  • 6 Ton 8HP Industrial Chiller System For Vacuum Coating Machine
  • 6 Ton 8HP Industrial Chiller System For Vacuum Coating Machine
  • 6 Ton 8HP Industrial Chiller System For Vacuum Coating Machine
  • 6 Ton 8HP Industrial Chiller System For Vacuum Coating Machine
  • 6 Ton 8HP Industrial Chiller System For Vacuum Coating Machine
  • 6 Ton 8HP Industrial Chiller System For Vacuum Coating Machine

6 Ton 8HP Industrial Chiller System For Vacuum Coating Machine

This 6 Ton/20KW industrial chiller is widely used in food indutry,plastic injection molding,plastic extruders,and extrusion lines,blowing molding machines,metal plating and so on.

Chiller Model:          TW-8AD

Cooling Capacity:    21.8KW(18748kcal/h) @ 50HZ 
                                25.5KW(21935 kcal/h) @ 60HZ

Refrigerant:             R22/R407c/R410a/R134A/R404a

Power Supply:         220V/50HZ /1PH (Standard)
                                208-240V/60HZ/1PH(Customized)

Compressor Brand:Panasonic Scroll Compressor

Evaporator Type:     Coil in SS Water Tank (Standard)
                                Shell and TubeType(Customized)




    6 Ton/8HP Industrial Chiller System

    6 Ton Industrial air cooled chiller unit uses aluminum fin+fan as condensers.Air cooled chiller absorbs heat from process water, and the heat is then transferred to the air around the chiller unit.
    6 Ton industrial air cooled chiller unit model TW-8AD includes a multi-stage hermetic scroll compressor using R410A/R407C refrigerant. The refrigerant is a non-depleting ozone gas and is considered environmentally friendly. 
    6 Ton industrial air cooled chiller is suitable for die casting, rubber, printing, plastic injection molding, beverage production, metal polishing, the pharmaceutical industries and other other industries.
    Tongwei is the top manufacturer and supplier of the 6 Ton water chiller, located in China. With many years of experience, we guarantee the production of the best quality 6 Ton water chiller with amazing specifications and super warranty offers.
    With the help of the efficient 6 Ton air cooled chiller, you can achieve effective cooling in any industry.

    1.How Does An 6 Ton Industrial Chiller System Work?


    2.What Are The Main Components Of Portable Chiller?

    2.1 Compressor
    The compressor is the key mover in Portable Air Cooled Water Chiller because it produces pressure variations to stir the refrigerant around.
    For 20KW industrial chiller system , which is with two units 4HP Panasonic brand compressor, using R410A/R407C refrigerant,this brand compress is with high refrigeration efficiency,low noise ,energy saving,environmental protection and durability,safety and stability. 

    Panasonic Compressor


    Danfoss Compressor

    2.2 Evaporator
    The evaporator is a crucial component of industrial air cooled chiller, as it is responsible for extracting heat from the liquid being cooled,it is located between the compressor and the expansion valve. There are three types of evaporators : coil in water tank evaporator , shell and tube evaporator, 304SS stainless steel plate type evaporator. 

    Coil in SS Water Tank Evaporator


     SS Plate Type+ Water Tank Evaporator



    Shell and Tube Evaporator

    2.3 Water Pump
    The water pump is designed to increase the pressure and the flow of the chilled water in a closed space. 
    the water pressure water pump for chiller is about 2 bar , but if you need more higher water pressure , pls tell us when you inquiry .For example ,when you use chillers for cooling bottle blowing machine ,the water pressure for water pump need about 4 bar .


    Water Pump


    High Pressure Water Pump

    2.4 Condenser

    The condenser for industrial air cooled chiller is equipped with efficient cross-seam fins and female threaded copper tubes for high heat exchange efficiency and good stability.Its function is to cool down the refrigerant steam released from the compressor into a liquid or gas-liquid mixture.

     
    Aluminum fin+fan Condenser

    2.5 Controller Panel
    Tongwei chillers use precision digital temperature controller, it RS485 communication port,which can do remote monitoring and control. Simple operation, low failure rate, high safety factor, easy installation.


    Controller Panel

    3. How I Can Choose The Right Indsutrial Chiller System?

    There are four important chiller specifications you need consider when you choose a chiller for your application :the voltage required for operation, the associated pump horsepower and flow rate (contact us for custom selection), refrigerant, and the evaporator type.

    3.1 Power

    Different countries and regions have different standards for industrial electricity, the common power supplies are 208-230V, 380-420V,440-480V,50Hz or 60Hz, 3phase.

    Such in Philippines ,the power supply is 220V 60HZ 3PH , 380V 60HZ 3PH ,460V 60HZ 3PH;

    in Singapore and Malaysia ,the power supply is 415V 50HZ 3PH;

    in Mexico ,the power supply is 220V 60HZ 3PH;

    In USA ,the power supply is 208V 60HZ 3PH;575V 60HZ 3PH;480V 60HZ 3PH and so on

    3.2 Water Pump

    When you decide the capacity/tonnage of the chiller, we will recommend you the suitable pump in KW,which standard water pump is about 2 bar .If you need more high water pressure , please us when you inquiry.

    3.3 Refrigerant

    R22, R410A, R407C, R404A, R134A are optional choices.

    R22: good cooling effect, but R22 is considered a powerful greenhouse gas, so it’s forbidden in most countries.

    R410A: eco-friendly, R-410A has replaced R-22 as the preferred refrigerant for use in residential and commercial air conditioners in Japan, Europe, and the United States. R-410A operates at higher pressures than other refrigerants.

    R407C: a good replacement for R22, good cooling effect.

    R404A: suitable for application that requires low temperature(below -10°c).

    R134A: a non-flammable gas used primarily as a “high-temperature” refrigerant, suitable for air-cooled chiller working at a high ambient temperature above 50℃.


    3.4 Evaporator Choose

    Chillers generally have two types of evaporators: one is coil in water tank evaporator ,the other one is shell and tube evaporator.

    Coil and tank evaporator, which has a built-in water storage tank for more convenient use,so there’s no need for extra buffer tanks. This is also our standard evaporator for chiller , if you don’t have buffer tank ,we just use this evaporator for your chiller.(See Above 2.2)

    Shell and tube type evaporator, which requires an additional water buffer tank to connect .(See Above 2.2)

    4.Features of Industrial Chiller System
    These portable air-cooled chillers have a 41-95°F(5~35℃) operational temperature range and work in maximum ambient temperature 104°F(40℃) cooling range feature with an environmentally friendly R410A or R407C refrigerant. If your ambient temperature can reach above 50℃ ,please choose environmentally friendly R134a refrigerant for high ambient temperature.
     
    Other standard features of the portable air-cooled chillers we supply include:

       ▪ Full diagnostics panel
       ▪ Reservoir tank
       ▪ Brazed plate/shell and tube/coil in water tank heat exchanger
       ▪ Pressure gauges (refrigerant and pump)
       ▪ Hot gas bypass valve
       ▪ Fin style condenser
       ▪ Filter dryer and moisture indicator
       ▪ Compact design with portable wheels
       ▪ Simple&easy installation low maintenance cost

    5.Contact Us to Learn More About Our Industrial Chiller System

    Don’t delay in making the best decision for your manufacturing business and your future by increasing your production capabilities with an air-cooled chiller. Contact us today for more information on a portable air cooled chiller.
    Our probessional team will help you with any questions you have on our portable air-cooled chiller units. We look forward to hearing from you!


                    8HP Industrial Air Cooled Chiller Technical    

                          Specifications MODEL:TW-8AD

    Model
    TW-8AD
    nominal cooling capacity
    KW
    50HZ
    21.8
    60HZ
    25.5
    Ton
    50HZ
    60HZ
    Chilled Water temperature range
    5~35
    Max power consumption
    kw
    7.25
    Full load
    Amp
    20
    power source
     
    3PH-3800V-50HZ (Standard)
    3PH-220-480V-60HZ(Customized)
    refrigerant
    type
     
    R22/R407C/R410A/R134A
    control
     
    Capillary
    compressor
    type
     
    hermetic scroll type
    power
    kw
    3*2
    QTY.
    Unit
    2
    condenser
    type
     
    Efficient aluminum finned copper sleeve+low noise external rotor fan
    air volume
    m3/h
    8000
    fan motor
    kw
    0.25*2
    evaporator
    type
     
    Coil in Water tank evaporator(Standard)
    Shell and tube Evaporator(Customized)
    Cooling water flow rate
    m3/h
    3.75
    Tank volume
    L
    130
    inlet and outlet connection(BSP)
    inch
       1-1/2’’
    Water pump
    power
    kw
                                 0.75
    Water Flow
    M3/h
                                  8.1
    Max.Pressure
    Bar
                                  2
    safety devices
    Compressor overheating protection,over-current protection,high and low pressure protection,over-temperature protection,traffic protection,phase sequence/phase loss protection,low level protection,frost protection
    dimension
    mm
    1450*690*1630
    weight
    kg
    290

    1. Testing results under the above conditions: Inlet/outlet chilled water temperature 12℃/7℃, condensing temperature 45℃.
    2.The above parameters will be updated continuously. If you have any special request, please send your technical requirements before placing an order.
    1.How does a chiller system work?
    Chiller has two circulation,one is process water circulation,the other is refrigerant gas circulation.Heat picked up from the process.Heat transfers to refrigerant circulation.Heat is remove to air or water.

    2.How to calculate right cooling capacity for chillers?
    One of the most frequently ask about how we can know the cooling capacity for chillers. Let’s see the below formula.
    Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-T2)/0.86
    Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)
    Oversize the chiller by 20% Ideal Size in KW = KW x 1.2
    Noted : T1:Incoming Water Temperature (℃)      T2:Required Chilled Water Temperature(℃)    
        
    For example, what size of chiller is required to cool 5m³ water from 25°c to 15 °c in 1 hour?
    Temperature Differential = 25℃-15℃=10℃
    Water Flow Rate = 5 m³/hour
    Cooling Capacity in KW = 5 x 10 ÷ 0.86 = 58,14 KW
    Oversize the chiller = 58.14 x 1.2 = 69.76 KW
    69.96kw cooling capacity for chiller is required.

    3.Types of chiller system?
    There are two types of chiller :Air Cooled Chiller and Water Cooled Chiller.
    Water cooled chiller needs a separated water cooling tower and water cooling pump ,if you don‘t have exsiting water cooling tower,we suggest you use air cooled chiller; But if your ambiemt temperature is very high above 55℃ ,we suggest you use water cooled chiller , as it is easier to dissipate heat for water cooled chiller with water cooling tower.

    4.Whether chillers need built-in Tank ornot?
    In a chiller system, a tank is usually equipped to buffer the thermal load of the chiller.
    But should we choose a built-in type of tank or an external type of tank?
    A chiller with a built-in tank is easier to install and can be used simply by connecting a water pipe to your application. 
    But it has a limited capacity and is not suitable for applications with larger chilled water demands.External tank’s capacity can be customized according to specific needs. 
    It can buffer a larger heat load, store more chilled water, but the installation will be more troublesome.
    If you don‘t have external water tank ,we suggest our chiller built-with water tank ,which is easy for you to install.

    5.Cooling capacity unit conversion?

       1 KW=860 kcal/h ; 

       1 TON=3.517 KW; 

       1 KW=3412 Btu/h;

    6.This chiller could do heat recovery?
    Yes,please kindly send us the temp and water volume per hour.

    7.Chiller maintenance?
    Step 1: Keep Tubes Clean
    Step 2: Ensure a Leak-free Unit
    Step 3: Sustain Proper Water Treatment(prevent scale, corrosion)
    Step 4: Analyze Oil and Refrigeran
    Please submit your basic information, we will contact you as soon as possible!

    *

    *

    File Name : Format: Size: Download:

Related products

  • Tel:+86 15320636029
  • Add:Fengxiang,Humen Town,Dongguan,China,
About Us77
Company Profile
Company culture
Factory Tour
Honor
Product
Industrial Chiller
Screw Chiller
Glycol Chiller
Explosion-Proof Chiller
Portable Chiller
Stationary Chiller
REQUEST QUOTE

Name

Email

Phone

Message

©2023 GuangDong TongWei Refrigeration Machinery Co., Ltd.   All rights reserved  
Web Design—Tiandixin