This 10 Ton portable water cooled packaged chiller with a standard capacity of 35KW circulate a fluid medium between -35℃ – 30℃. Designed, engineered and manufactured with non-proprietary components, portable water cooled packaged chillers from Tongwei are designed to last and are built for high performance in various industrial cooling applications.

Chiller Model:          TW-12WD

Cooling Capacity:    38KW(32680 kcal/h) @ 50HZ 
                                45.6KW(39216 kcal/h) @ 60HZ

Refrigerant:             R22/R407c/R410a/R134A/R404a

Power Supply:         380V/50HZ /3PH (Standard)
                                208-480V/60HZ/3PH(Customized)

Compressor Brand: Panasonic Scroll Compressor

Evaporator Type:     Coil in SS Water Tank (Standard)
                                Shell and Tube(Customized)
    This 10 Ton Portable water cooled packaged chiller is designed to be portable, making it easy to move around the industrial facility. Portable chiller can be used and installed in different locations, making it a cost-effective solution for your cooling needs. The chiller is easy to use and comes with a user-friendly control panel, allowing you to adjust the settings quickly and without any hassle.

    Portable water cooled packaged chillers feature a non-ferrous construction which guarantees against rust and prolongs the life of the chiller. Panasonic scroll compressor ,304 stainless steel water pump, stainless steel coil in water tank evaporator to keep your cooling process free of rust contaminates and keep the chiller running more efficiently .

    Each portable water cooled packaged chiller is factory tested before shipping to ensure top quality.

    For over 20 years Tongwei has engineered, designed and manufactured both portable water cooled and air cooled packaged chillers and are experts in process temperature control.

    1.What Are The Main Components Of 10 Ton Portable Water Cooled Packaged Chiller?

    1.1 Compressor
    The compressor is the key mover in portable Water Cooled Packaged Chiller because it produces pressure variations to stir the refrigerant around.
    For 10 Ton chiller , which is with two units 6HP Panasonic brand compressor, using R410A/R407C refrigerant,this brand compress is with high refrigeration efficiency,low noise ,energy saving,environmental protection and durability,safety and stability. 

    Panasonic Compressor

    1.2 Evaporator
    The evaporator is a crucial component of water cooled packaged chiller, as it is responsible for extracting heat from the liquid being cooled,it is located between the compressor and the expansion valve. There are three types of evaporators : coil in water tank evaporator , shell and tube evaporator, 304SS stainless steel plate type evaporator. 

    Coil in SS Water Tank Evaporator



     SS Plate Type+ Water Tank Evaporator



    Shell and Tube Evaporator

    1.3 Water Pump
    The water pump is designed to increase the pressure and the flow of the chilled water in a closed space. 
    the water pressure water pump for chiller is about 2 bar , but if you need more higher water pressure , pls tell us when you inquiry .For example ,when you use chillers for cooling bottle blowing machine ,the water pressure for water pump need about 4 bar .


    Water Pump


    High Pressure Water Pump

    1.4 Condenser

    The condenser for protable water cooled packaged chiller is shell and tube ,with the internal copper tubes employing an outer thread embossing process.This design effectively enhances the heat exchange efficiency between the refrigerant and water during the process. Compared to traditional smooth copper tubes, the outer thread embossing process increases the surface area of the copper tubes, thereby expanding the contact area for heat exchange and improving the thermal conductivity of the condenser. This optimization design allows the condenser of the water-cooled chiller to transfer heat from the refrigerant to the water more rapidly and consistently, enabling the water to carry away the heat.

     
    Shell and tube Condenser

    1.5 Controller Panel
    Tongwei chillers use precision digital temperature controller, it RS485 communication port,which can do remote monitoring and control. Simple operation, low failure rate, high safety factor, easy installation.


    Controller Panel

    2.Features of Portable Water Cooled Packaged Chillers
    These portable water-cooled packaged chillers have a -35~35℃) operational temperature range and work in maximum ambient temperature 131°F(55℃) cooling range feature with an environmentally friendly R410A or R407C refrigerant as it connects with water cooling tower for heat dissipate.
     
    Other standard features of the portable water-cooled chillers we supply include:

       ▪ Full diagnostics panel
       ▪ Reservoir tank
       ▪ Brazed plate/shell and tube/coil in water tank heat exchanger
       ▪ Pressure gauges (refrigerant and pump)
       ▪ Hot gas bypass valve
       ▪ Fin style condenser
       ▪ Filter dryer and moisture indicator
       ▪ Compact design with portable wheels
       ▪ Simple&easy installation low maintenance cost

    3.How I Can Choose The Right Portable Water Cooled Packaged Chiller?

    There are four important chiller specifications you need consider when you choose a chiller for your application :the voltage required for operation, the associated pump horsepower and flow rate (contact us for custom selection), refrigerant, and the evaporator type.

    3.1 Power

    Different countries and regions have different standards for industrial electricity, the common power supplies are 208-230V, 380-420V,440-480V,50Hz or 60Hz, 3phase.

    Such in Philippines ,the power supply is 220V 60HZ 3PH , 380V 60HZ 3PH ,460V 60HZ 3PH;

    in Singapore and Malaysia ,the power supply is 415V 50HZ 3PH;

    in Mexico ,the power supply is 220V 60HZ 3PH;

    In USA ,the power supply is 208V 60HZ 3PH;575V 60HZ 3PH;480V 60HZ 3PH and so on

    3.2 Water Pump

    When you decide the capacity/tonnage of the chiller, we will recommend you the suitable pump in KW,which standard water pump is about 2 bar .If you need more high water pressure , please us when you inquiry.

    3.3 Refrigerant

    R22, R410A, R407C, R404A, R134A are optional choices.

    R22: good cooling effect, but R22 is considered a powerful greenhouse gas, so it’s forbidden in most countries.

    R410A: eco-friendly, R-410A has replaced R-22 as the preferred refrigerant for use in residential and commercial air conditioners in Japan, Europe, and the United States. R-410A operates at higher pressures than other refrigerants.

    R407C: a good replacement for R22, good cooling effect.

    R404A: suitable for application that requires low temperature(below -10°c).

    R134A: a non-flammable gas used primarily as a “high-temperature” refrigerant, suitable for air-cooled chiller working at a high ambient temperature above 50℃.


    3.4 Evaporator Choose

    Chillers generally have two types of evaporators: one is coil in water tank evaporator ,the other one is shell and tube evaporator.

    Coil and tank evaporator, which has a built-in water storage tank for more convenient use,so there’s no need for extra buffer tanks. This is also our standard evaporator for chiller , if you don’t have buffer tank ,we just use this evaporator for your chiller. 

    Shell and tube type evaporator, which requires an additional water buffer tank to connect . 

    4.How Choose Water Cooling Tower For Your Portable Water Cooled Pacakged Chiller?

    There are three important temperature factors you need to consider when choosing a cooling tower for water cooled screw chiller: inlet hot water temperature, outlet cold water temperature, and wet bulb temperature. The hot water temperature is that which enters the tower. The cold water temperature is that which leaves the water while the wet bulb temperature refers to the prevailing temperature of the geographic region where the tower is located.

    Approach is the term used to refer to the difference between the temperatures of the water source as it enters the tower versus the temperature of the water once it has left the tower. This is a crucial determiner of the effective of the heat exchange process.

    To choose the right cooling tower, mechanical efficiency should be given priority. This refers to the amount of fan power needed to circulate ambient air within the cooling tower. The range – or the difference in temperature between hot and cold water – is also crucial as it will impact energy usage.

    so to find out how to choose a cooling water tower with sufficient cooling capacity, you should understand what circumstances require the use of a cooling tower. Please find the below water cooling tower is suitable for water cooled screw chiller :

    Cooling Capacity of Chiller                            Water Cooling Tower Capacity 


    5HP(16KW/4 Ton)                                            15 Ton


    6HP(19KW/5 Ton)                                            15 Ton


    8HP(25KW/7 Ton)                                            20 Ton


    10HP(30KW/8 Ton)                                           20 Ton


    12HP(40KW/11 Ton)                                          25 Ton


    15HP(50KW/14 Ton)                                          25Ton


    20HP(65KW/18 Ton)                                          30 Ton


    25HP(80KW/22 Ton)                                           40Ton


    30HP(100KW/28 Ton)                                         40 Ton


    40HP(130KW/37 Ton)                                          50 Ton


    50HP(153KW/43Ton)                                            60 Ton
    60HP(200KW/56 Ton)                                           80 Ton

    5.What is the Difference Between Portable Air Cooled Packaged Chiller and Portable Water Cooled Pacakged Chiller?

    Portable Air-cooled and portable water-cooled pacakged chillers are both types of chillers used for cooling applications in various industries.
    The main difference between portable air cooled  chiller and portable water cooled pacakged chiller is condenser :
    The condenser of an portable air cooled  packaged chiller is cooled by the ambient air,which the heat generated during the cooling process is dissipated into the surrounding air;

    Portable Water Cooled Chiller with a shell and tube water-type condenser that is attached to a cooling tower and is typically used in medium and wide installations where water is available.So Water cooled screw chiller need connect with water cooling tower and water cooling pump outside , the installation is more trouble than air cooled screw chiller .
    But if your ambient temperature is very high above 50℃,we suggest you use portable water cooledchiller ,as portable water cooled chiller may consume more energy to achieve the same cooling capacity due to the limitations of air as a heat exchange medium and portable water cooled chiller uses constant water source for more stable and efficient heat dissipation,so in high ambient temperature , portable water cooled chiller is more energy-efficient and better choice for your application .


    Portable Air Cooled  Pacakged Chiller

    6.Contact Us to Learn More About Our 10 Ton Portable  Water Cooled Pacakged Chillers

    Don’t delay in making the best decision for your manufacturing business and your future by increasing your production capabilities with an water-cooled chiller. Contact us today for more information on a portable water cooled packaged chiller.
    Our probessional team will help you with any questions you have on our portable water cooled pacakged chiller units. We look forward to hearing from you!


    TW-W Series Portable Water Cooled Packaged Chiller Techinical Parameters
                                     Model                               Item TW-3W TW-4W TW-5W TW-6W TW-8WD TW-10WD TW-12WD TW-15WD TW-15WT TW-20WD
    Cooling
    capacity
    kcal/h
    50HZ/60HZ
    8170 11266 14018 16340 22532 28036 32680 43172 42140 56760
    9804 13519 16822 19608 27038 33643 39216 51806 50568 68112
    KW
    50HZ/60HZ
    9.5 13.1 16.3 19 26.2 32.6 38 50.2 49 66
    11.4 15.72 19.56 22.8 31.44 39.12 45.6 60.24 58.8 79.2
    Input power KW 3.07 3.87 5.3 5.95 7.75 10.6 11.9 16.25 15.85 19.71
    Max Current A 7.5 9.4 12.9 14.4 18,8 25.7 28.9 39.4 38.2 47.8
    power source 3PH380V/415V50HZ/60HZ(3PH200V/220V50HZ/60HZ)
    Refrigerant Type  R22/R407C/134a/404A/410A
    Control Capillary/External balance thermal expansion valve
    Compressor Type Hermetic scroll ( piston )
    Power(KW) 2.7 3.5 4.55 5.2 3.5×2 4.55×2 5.2×2 7×2 4.55×3 8.96×2
    Condenser Type shell and tube 
    Cooling water
     volume (m3/h)
    2.1 2.9 3.6 4.2 5.7 7.1 8.3 11 10.8 14.4
    2.4 3.3 4.1 4.8 6.6 8.3 9.6 12.8 12.5 16.7
    Pipe connection(Inch) 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 2" 2" 2"
    Evaporator Type Tank with cooper coil / Shell and tube/Plate heat exchanger
    Chilled water
        volume((m3/h)
    1.63 2.25 2.8 3.27 4.5 5.6 6.53 8.63 8.43 11.35
    1.96 2.7 3.36 3.92 5.4 6.73 7.84 10.36 10.1 13.62
    water tankL 60 60 60 90 150 200 200 330 330 330
    Pipe connection(Inch) 1" 1" 1" 1" 1-1/2" 2" 2" 2" 2" 2"
    Water pump Power(kw) 0.37 0.37 0.75 0.75 0.75 1.5 1.5 2.2 2.2 2.2
    Max lift(m) 22 22 30 30 25 25 25 28 28 28
    Max flow (m3) 5.4 5.4 8.1 8.1 8.1 13.5 13.5 25.2 25.2 25.2
    Safety devices Compressor overheating protection,overcurrent protection,high and low pressure protection,overtemperature protection,traffic protection,phase sequence/phase loss protection,low level protection,anti-freezing protection.
    Dimension Lengthmm 910 910 910 910 1250 1250 1250 1600 1600 1600
    Widthmm 480 480 480 480 680 680 680 750 750 750
    Heightmm 1000 1000 1000 1000 1380 1380 1380 1600 1600 1600
    Weight Kg 125 135 160 180 230 260 330 420 420 460
    Notes:
    1.Rated cooling capacity is based on: chilled water inlet and outlet water temperature 12  / 7 , the cooling water inlet and outlet temperature 25  / 30  
    2.Scope of work: chilled water temperature range: 5 
     to 35 ; chilled water inlet and outlet temperature difference: 3  to 8 .
    Cooling water temperature range: 18 
     to 37 ; cooling water inlet and outlet temperature difference: 3.5  to 10 
    1.How does a chiller system work?
    Chiller has two circulation,one is process water circulation,the other is refrigerant gas circulation.Heat picked up from the process.Heat transfers to refrigerant circulation.Heat is remove to air or water.

    2.How to calculate right cooling capacity for chillers?
    One of the most frequently ask about how we can know the cooling capacity for chillers. Let’s see the below formula.
    Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-T2)/0.86
    Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)
    Oversize the chiller by 20% Ideal Size in KW = KW x 1.2
    Noted : T1:Incoming Water Temperature (℃)      T2:Required Chilled Water Temperature(℃)    
        
    For example, what size of chiller is required to cool 5m³ water from 25°c to 15 °c in 1 hour?
    Temperature Differential = 25℃-15℃=10℃
    Water Flow Rate = 5 m³/hour
    Cooling Capacity in KW = 5 x 10 ÷ 0.86 = 58,14 KW
    Oversize the chiller = 58.14 x 1.2 = 69.76 KW
    69.96kw cooling capacity for chiller is required.

    3.Types of chiller system?
    There are two types of chiller :Air Cooled Chiller and Water Cooled Chiller.
    Water cooled chiller needs a separated water cooling tower and water cooling pump ,if you don‘t have exsiting water cooling tower,we suggest you use air cooled chiller; But if your ambiemt temperature is very high above 55℃ ,we suggest you use water cooled chiller , as it is easier to dissipate heat for water cooled chiller with water cooling tower.

    4.Whether chillers need built-in Tank or not?
    In a chiller system, a tank is usually equipped to buffer the thermal load of the chiller.
    But should we choose a built-in type of tank or an external type of tank?
    A chiller with a built-in tank is easier to install and can be used simply by connecting a water pipe to your application. 
    But it has a limited capacity and is not suitable for applications with larger chilled water demands.External tank’s capacity can be customized according to specific needs. 
    It can buffer a larger heat load, store more chilled water, but the installation will be more troublesome.
    If you don‘t have external water tank ,we suggest our chiller built-with water tank ,which is easy for you to install.

    5.Cooling capacity unit conversion?

       1 KW=860 kcal/h ; 

       1 TON=3.517 KW; 

       1 KW=3412 Btu/h;

    6.This chiller could do heat recovery?
    Yes,please kindly send us the temp and water volume per hour.

    7.Chiller maintenance?
    Step 1: Keep Tubes Clean
    Step 2: Ensure a Leak-free Unit
    Step 3: Sustain Proper Water Treatment(prevent scale, corrosion)
    Step 4: Analyze Oil and Refrigerant
    Please submit your basic information, we will contact you as soon as possible!

    *

    *

    File Name : Format: Size: Download:

Related products

  • Tel:+86 15320636029
  • Add:Fengxiang,Humen Town,Dongguan,China,
About Us77
Company Profile
Company culture
Factory Tour
Honor
Product
Industrial Chiller
Screw Chiller
Glycol Chiller
Explosion-Proof Chiller
Portable Chiller
Stationary Chiller
REQUEST QUOTE

Name

Email

Phone

Message

©2023 GuangDong TongWei Refrigeration Machinery Co., Ltd.   All rights reserved  
Web Design—Tiandixin