• +86 15320636029
  • info@cooling-chiller.com
REQUEST A QUOTE
Product

Product

Contact

You are here:Home >> Product >> Glycol Chiller >> Water Cooled Glycol Screw ...

Water Cooled Glycol Screw Chiller

50HP Industrial Water Cooled Screw Low Temperature Chiller
  • 50HP Industrial Water Cooled Screw Low Temperature Chiller

50HP Industrial Water Cooled Screw Low Temperature Chiller

This 50HP/40 Ton low temperature water cooled screw glycol chiller can cool your application reach -10℃, which is widely used in winery , brewery ,distillery ,fermentation cooling process.

Chiller Model:          TW-50WSL

Cooling Capacity:    93.8KW(80668 kcal/h) @ -10℃
                                63KW(54180kcal/h) @ -20℃
                                41.3KW(35518kcal/h) @ -30℃

Refrigerant:             Environmental Friendly R404a

Power Supply:         380V/50HZ /3PH (Standard)
                                208-480V/60HZ/3PH(Customized)

Compressor Brand: Hanbell/Bizter ScrewCompressor

Evaporator Type:    Shell and Tube 

Condenser Type:     Shell and Tube     

             
    At general refrigeration systems, our aim is to provide affordable cooling solutions to a wide range of industries by offering standard packaged units as well as units custom-made to your specifications.
    We have designed our air-cooled glycol chillers to accommodate a range of low temperature applications,such as breweries,distilleries,wineries, pharmaceutical,and food& beverage industry.
    We know that not every application requires such low temperature, so we provide cooling capacity by leaving fluid temperature charts for our most popular models.
    Glycol is recommended for all chiller units when operating temperatures are below 41°F (5°C).
    2.What is Glycol Chiller ?
    A glycol chiller ,also called a low temperature chiller or glycol refrigeration system, is an industrial process chiller that uses a water and glycol mixture as a coolant which allows it to efficiently transfer heat and maintain temperature control in different kinds of industrial applications, particularly in applications that involve cooling liquids or equipment.


    Water Cooled Glycol Screw Chiller

    3.What Are The Main Components Of Water Cooled Screw Glycol Chiller ?

    3.1 Compressor
    The compressor is the key mover in Water Cooled Screw Glycol Chiller because it produces pressure variations to stir the refrigerant around.
    For 50hHP chiller , which is with 1 units Hanbell Screw brand or Bizter Screw compressor for optional depends on the required refrigeration capacity, using R404A refrigerant,this brand compress is with high refrigeration efficiency,low noise ,energy saving,environmental protection and durability,safety and stability. 
    Each screw compressor with 4 steps of energy control 25%-50%-75%-100% to make sure the whole screw chiller is stable and guarantee high refrigeration performance. 

    Hanbell Screw Compressor


    Bizter Screw Compressor

    3.2 Evaporator
    The evaporator is a crucial component of  water cooled screw chiller, as it is responsible for extracting heat from the liquid being cooled,it is located between the compressor and the expansion valve. Water CooledScrew Chiller Uses highly efficient closed loop shell and tube type heat exchanger as the evaporator.

    Shell and Tube Evaporator

    3.3 Condenser

    The condenser for water cooled screw chiller is water-cooed type shell and tube for high heat exchange efficiency and good stability.Its function is to cool down the refrigerant steam released from the compressor into a liquid or gas-liquid mixture.

     
    Water-cooled type Shell and Tube Condenser

    3.4 Controller Panel
    Tongwei chillers use Integrated PLC control system with human-computer interface and big LED touch screen panel.


    4.What is the Difference Between Water Cooled Glycol Scroll Chiller and Water Cooled Glycol Screw Chiller?

    Water Cooled Glycol Scroll Chiller                                 Water Cooled Glycol Screw Chiller 

    ▪ 3HP-60HP                                                                        Above 60HP

    ▪ Danfoss/Panasonic Scroll Compressor                           Hanbell/Bitzer Screw compressor

    ▪Built with water tank and water pump                               Without water tank and water pump
           
                    

       Water Cooled Glycol Scroll Chiller                                                                               Water Cooled Glycol Screw Chiller


    5.Why Glycol Is Used for Cooling?
    The most commonly used coolant in a chiller is water or a mixture of water-glycol. Glycol-based coolants consist of either ethylene glycol or propylene glycol. The main advantage of glycol coolants is their anti-freeze properties. Pure water freezes at 0 degrees C, while 30% ethylene glycol freezes at -14 degrees C. The low freezing point of glycol mixtures makes them ideal for cooling items that are below the freezing point of water. Although glycol has a lower heat capacity than water (each kilogram of glycol is easier to heat than one kilogram of water), the high temperature difference allows the glycol mixture to dissipate heat more quickly than pure water. The glycol mixtures are more suitable for applications where the chiller must quickly dissipate a large number of heat. In addition to providing excellent heat transfer parameters, glycol tends to discourage algae growth in heat transfer equipment.

    Comparison of Ethylene Glycol and Propylene Glycol

    Property                                                  Ethylene Glycol                                       Propylene Glycol

    Freeze point depression                          More effective                                        Less effective

    Heat transfer efficiency/capacity          Better                                                       Less

    Viscosity                                                  Lower                                                       Higher

    Flammability                                       Low                                                               Low

    Chemical Oxygen Demand                Low                                                         Higher

    Biodegrading                                          Degradesin 10-30 days                                        Needs more than 20-30 days to degrade

    Carcinogenic                                             No                                                                 No

    Toxic                                              High level of acute when taken orally,                Lower level of acute
                                                                 
    targets the kidneys

    Skin Irritant                                                Low                                                            Low

    Ethylene Gycol And Propylene Glycol

    6. How Does A Glycol Chiller Work?
    A glycol chiller is composed of a refrigeration component and tubing containing a water-glycol mixture as coolant. Chilled fluid from the refrigeration unit is channeled through the piping associated with a thermal exchanger surrounding a heated process. After absorbing heat from the associated process, the hot coolant is returned to the refrigeration unit for cooling after which the process is repeated.
    A glycol chiller consists of a compressor, an evaporator, a condenser, a throttling element, and an electric control system. Let’s see what’s the working principle of a glycol chiller:



      Glycol Chiller Working Principle


    7.The Ratio of Water to Glycol to Use

    It is important to use the proper ratio of glycol to water mixture in the cooling system depends on the coldest temperature you need during operation, as insufficient glycol can cause the system to freeze, possibly bursting pipes and even destroying the chiller evaporator even may damage the glycol chiller, while too much glycol to a chiller system will result in an inefficient system.
    But what’s the best ratio for glycol and water mixtures? Pls see below glycol ratio of glycol and water mixtures for the glycol chillerin your cooling process:

    Glycol                                               Water                          Water Temperature

    16%                                                 84%                                           0℃

    24%                                                 76%                                           -5℃

    32%                                                 68%                                           -10℃

    40%                                                 60%                                           -15℃

    45%                                                 55%                                           -20℃

    50%                                                 50%                                           -25℃

    55%                                                 45%                                           -30℃


    8.What Applications Can A Glycol Chiller Be Used For?
    Glycol chiller is a specific kind of cooling system,which is  used to cool a variety of liquids and other industrial applications.
    By using a glycol chiller can achieve the low temperature for your industrial usage you need .
    Glycol chillers are most used for below these Industries:
    8.1 Breweries 
    In breweries, the glycol chiller is used for cooling the wort,Controlling Fermentation,Crash Cooling Vessels,Prepackaging and Product Storage.
    Glycol Chiller for Breweries

    8.2 Wineries
    Glycol chillers are widely used in the fermentation process, cold stabilization and room cooling purposes.
    Glycol Chiller for Wineries

    8.3 Cider Mills
    Fermentation control needs critical water temperature control.  Glycol chiller can provide cold chilling of the juice and milk, also the cold storage of the final product.


    Glycol Chiller for Cider Mills

    8.4 Distilleries
    During the fermentation process, the glycol chiller will provide a steady coolant for circulation between distillation tanks & stills for heat removal purposes.

    Glycol Chiller for Distilleries

    8.5 Food Industry.
    Glycol chillers can provide low-temperature coolant to guarantee the safety and consistent quality of frozen foods, food processing companies need a low-temperature cooling day in and day out.
    Glycol Chiller for Food Industry
    8.6 Dairy Product
    A properly designed dairy glycol chiller can cool the milk very rapidly to help keep milk temperatures (and bacteria growth) under control as it is transferred from the milking parlor to its insulated tank.
    Glycol Chiller for Dairy Product


    Do you need a glycol chiller for an application not mentioned here? Contact us and we’ll customize an affordable solution for your exact demands.

    9.How to Choose Right Glycol Chiller for your Application?
    It is very important to select the right glycol Chiller for application process, if you want proper and durable cooling,please see blow key points:
    9.1 Air-Cooled Screw Glycol Chiller or Water-Cooled Screw Glycol Chiller
    There are two types of glycol chiller: one is air-cooled type, the other one is water-cooled type.
    Air cooled screw glycol chillers use aluminum fin+fan as condensers that is similar to the “radiators” in a car.They use a fan to force air through the refrigerant coil. Unless they are specifically designed for high ambient conditions, air-cooled condensers need to operate effectively at an ambient temperature of 45℃ or less.
    Water cooled screw glycol chiller use shell and tube as condensers.The heat enters the condenser water from the refrigerant vapor. The warm condenser water is then pumped to the water cooling tower, where the heat from the process is eventually vented to the atmosphere.

    Air-cooled Screw Glycol Chiller Installation for Reference



    Water-cooled Glycol Chiller Installation for Reference

    9.2 Cooling capacity
    When you choose a suitable chiller model , you need to know the cooling capacity in KW/TON.How to calculate the cooling capacity you need? Please see the below formula:
    Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-T2)/0.86
    Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)
    Oversize the chiller by 20% Ideal Size in KW = KW x 1.2
    Noted : T1:Incoming Water Temperature (℃)      T2:Required Chilled Water Temperature(℃)    
        
    For example, what size of chiller is required to cool 5m³ water from 25°c to 15 °c in 1 hour?
    Temperature Differential = 25℃-15℃=10℃
    Water Flow Rate = 5 m³/hour
    Cooling Capacity in KW = 5 x 10 ÷ 0.86 = 58,14 KW
    Oversize the chiller = 58.14 x 1.2 = 69.76 KW
    69.96kw cooling capacity for chiller is required.

    9.3 Power
    Different countries and regions have different standards for industrial electricity, the common power supplies are 208-230V, 380-420V,440-480V,50Hz or 60Hz, 3phase.
    Such in Philippines ,the power supply is 220V 60HZ 3PH , 380V 60HZ 3PH ,460V 60HZ 3PH;
    in Singapore and Malaysia ,the power supply is 415V 50HZ 3PH;
    in Mexico ,the power supply is 220V 60HZ 3PH;
    In USA ,the power supply is 208V 60HZ 3PH;575V 60HZ 3PH;480V 60HZ 3PH and so on

    9.4 Water Pump
    When you decide the capacity/tonnage of the chiller, we will recommend you the suitable pump in KW,which standard water pump is about 2 bar .If you need more high water pressure , please us when you inquiry.

    9.5 Water cooled screw chiller generally uses one evaporators: just is shell and tube heat exchanger.

    Shell and tube type evaporator, which requires an additional water buffer tank to connect.

    9.6 Buffer Water Tank Capacity Choose

    Buffer tank’s capacity can be customized according to specific needs. It can buffer a larger heat load, store more chilled water .


    304 Stainless Steel Water Tank 

    10.Contact Us to Learn More About Our Low Temperature Air Cooled Glycol Chiller

    Don’t delay in making the best decision for your manufacturing business and your future by increasing your production capabilities with low temperature glycol chillers. Contact us today for more information on a chiller.
    Our probessional team will help you with any questions you have on our chiller units. We look forward to hearing from you!


                  50HP Water Cooled Glycol Screw Chiller 
     
                Technical Specifications MODEL:TW-50WSL



    Model
    TW-50WSL
    nominal cooling capacity
    KW
    -10℃
    93.8
    -20℃
    63
    -30℃
    41.3
    Chilled Water temperature range
    -30~5
    Max power consumption
    kw
    38
    Full load
    Amp
    121
    power source
     
    3PH-380V-50HZ (Standard)
    3PH-220-480V-60HZ(Customized)
    refrigerant
    type
     
    R404A
    Charge Amount
    KG
    36
    control
     
    External balance of thermal expansion valve
    compressor
    type
     
    Semi-hermetic screw type
    power
    kw
    38
    Start Mode
     
    Y-
    condenser
    type
     
    Shell and tube condenser
    cooling water
    m3/h
    32.3
    Water Resistance
    Kpa
    42
    Diameter
    inch
    3"
    evaporator
    type
     
    shell and tube Type Evaporator
    Chilled water m3/h
    -10℃
    16.1
    -20℃
    10.8
    -30℃
    7.1
    Water Resistance
    Kpa
                   35
    inlet and outlet connection(BSP)
    inch
                        3’’
    safety devices
    Compressor overheating protection,over-current protection,high and low pressure protection,over-temperature protection,traffic protection,phase sequence/phase loss protection,low level protection,frost protection
    dimension
    mm
    2500*1000*1300
    weight
    kg
    1100
     
    1.How does a chiller system work?
    Chiller has two circulation,one is process water circulation,the other is refrigerant gas circulation.Heat picked up from the process.Heat transfers to refrigerant circulation.Heat is remove to air or water.

    2.How to calculate right cooling capacity for chillers?
    One of the most frequently ask about how we can know the cooling capacity for chillers. Let’s see the below formula.
    Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-T2)/0.86
    Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)
    Oversize the chiller by 20% Ideal Size in KW = KW x 1.2
    Noted : T1:Incoming Water Temperature (℃)      T2:Required Chilled Water Temperature(℃)    
        
    For example, what size of chiller is required to cool 5m³ water from 25°c to 15 °c in 1 hour?
    Temperature Differential = 25℃-15℃=10℃
    Water Flow Rate = 5 m³/hour
    Cooling Capacity in KW = 5 x 10 ÷ 0.86 = 58,14 KW
    Oversize the chiller = 58.14 x 1.2 = 69.76 KW
    69.96kw cooling capacity for chiller is required.

    3.Types of chiller system?
    There are two types of chiller :Air Cooled Glycol Chiller and Water Cooled Glycol Chiller.
    Water cooled chiller needs a separated water cooling tower and water cooling pump ,if you don‘t have exsiting water cooling tower,we suggest you use air cooled chiller; But if your ambiemt temperature is very high above 55℃ ,we suggest you use water cooled chiller , as it is easier to dissipate heat for water cooled chiller with water cooling tower.

    4.Whether chillers need built-in Tank ornot?
    In a chiller system, a tank is usually equipped to buffer the thermal load of the chiller.
    But should we choose a built-in type of tank or an external type of tank?
    A chiller with a built-in tank is easier to install and can be used simply by connecting a water pipe to your application. 
    But it has a limited capacity and is not suitable for applications with larger chilled water demands.External tank’s capacity can be customized according to specific needs. 
    It can buffer a larger heat load, store more chilled water, but the installation will be more troublesome.
    If you don‘t have external water tank ,we suggest our chiller built-with water tank ,which is easy for you to install.

    5.Cooling capacity unit conversion?

       1 KW=860 kcal/h ; 

       1 TON=3.517 KW; 

       1 KW=3412 Btu/h;

    6.Can ethylene glycol be used for cooling? What are the advantages?

    The main advantage of glycol coolants is their antifreeze properties. Glycol mixtures are perfect for cooling things because they have a lower freezing point than water. Thirty percent ethylene glycol freezes at 6.8°F (-14°C), while pure water freezes at 32°F (0°C).


    7.How Often Should Ethylene Glycol Be Changed?
    We recommend mixing distilled water and 100% USP propylene glycol at a ratio of 1 part ethylene glycol to 2 parts water. Inhibiting ethylene glycol is possible but not required. We recommend an annual glycol solution change as a maintenance routine for your glycol chiller.
    Please submit your basic information, we will contact you as soon as possible!

    *

    *

    File Name : Format: Size: Download:

Related products

  • Tel:+86 15320636029
  • Add:Fengxiang,Humen Town,Dongguan,China,
About Us77
Company Profile
Company culture
Factory Tour
Honor
Product
Industrial Chiller
Screw Chiller
Glycol Chiller
Explosion-Proof Chiller
Portable Chiller
Stationary Chiller
REQUEST QUOTE

Name

Email

Phone

Message

©2023 GuangDong TongWei Refrigeration Machinery Co., Ltd.   All rights reserved  
Web Design—Tiandixin