• +86 15320636029
  • info@cooling-chiller.com
REQUEST A QUOTE
Product

Product

Contact

You are here:Home >> Product >> Screw Chiller >> Water Cooled Screw Chiller...

Water Cooled Screw Chiller

50 TR To 500 TR Water Cooled Screw Chiller
  • 50 TR To 500 TR Water Cooled Screw Chiller
  • 50 TR To 500 TR Water Cooled Screw Chiller
  • 50 TR To 500 TR Water Cooled Screw Chiller
  • 50 TR To 500 TR Water Cooled Screw Chiller

50 TR To 500 TR Water Cooled Screw Chiller

50 TR to 500 TR water cooled screw chiller is specially desinged by Tongwei for providing precise temperature control for large buildings and industrial applications that require process cooling. This chiller adopts semi-hermetic screw compressor, high-efficiency shell and tube heat exchanger and eco-friendly R407c refrigerant. The cooling capacity under nominal working condition is 170-1700kW.
    50 TR To 500 TR Water Cooled Screw Chiller 

    Water cooled screw chiller is type of water cooled chiller,which is refrigeration machine manufactured by Tongwei with a wide ranging from 50 TR to 400 TR cooling capacity and it is composed by water-cooled condenser, shell and tube type evaporator, expansion valves, PLC controller, power supply,one or two screw compressor that provides high efficiency levels,and an oil management system that ensures efficient operation and longer lifespan. The cooling tower and water pump are also main parts that provide a chilled water supply for heat discarding.

    Tongwei water cooled screw chillers are suited to be used in applications with high ambient temperature above 50℃, providing higher efficiency and lower cost in contrast to air cooled chillers. The screw compressor used in the chiller can offer 20%-30% higher efficiency than common compressor.Water cooled screw chiller is widely used in large refrigeration machine that used in hospitals, markets, large buildings, and industrial application such as plastic industry, pharmaceuticals, food, and beverage industry, die-cutting and etc.

    A wide option of cooling capacities from 170kW to 1700kW is available to meet customer‘s application needs.All models of water cooled screw chiller can be custom manufactured per your specific demands. Please contact us now if you have request! 






    1.How Does Water Cooled Screw Chiller Work?


    Water Cooled Screw Chiller with Buffer Water Tank Outside Installation for Reference

    2.What Are The Main Components Of Water Cooled Screw Chiller ?

    2.1 Compressor
    The compressor is the key mover in Water Cooled Screw Chiller because it produces pressure variations to stir the refrigerant around,which is with 1 or 2 units Hanbell Screw brand or Bizter Screw compressor for optional depends on the required refrigeration capacity, using R407C refrigerant,this brand compress is with high refrigeration efficiency,low noise ,energy saving,environmental protection and durability,safety and stability. 
    Each screw compressor with 4 steps of energy control 25%-50%-75%-100% to make sure the whole screw chiller is stable and guarantee high refrigeration performance. 

    Hanbell Screw Compressor


    Bizter Screw Compressor

    2.2 Evaporator
    The evaporator is a crucial component of  water cooled screw chiller, as it is responsible for extracting heat from the liquid being cooled,it is located between the compressor and the expansion valve. Water CooledScrew Chiller Uses highly efficient closed loop shell and tube type heat exchanger as the evaporator.

    Shell and Tube Evaporator

    2.3 Condenser

    The condenser for water cooled screw chiller is water-cooed type shell and tube for high heat exchange efficiency and good stability.Its function is to cool down the refrigerant steam released from the compressor into a liquid or gas-liquid mixture.

     
    Water-cooled type Shell and Tube Condenser

    2.4 Controller Panel
    Tongwei chillers use Integrated PLC control system with human-computer interface and big LED touch screen panel.


    PLC Controller Panel

    3.How I Can Choose The Right Water Cooled Screw Chiller?

    There are four important chiller specifications you need consider when you choose a chiller for your application :the cooling capacity for chiller ,the voltage required for operation, the associated pump horsepower and flow rate (contact us for custom selection), refrigerant, and the evaporator type.

    3.1 Calculate Right Cooling Capacity For Chillrs
    One of the most frequently ask about how we can know the cooling capacity for chillers. Let’s see the below formula.

    Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-T2)/0.86
    Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)
    Oversize the chiller by 20% Ideal Size in KW = KW x 1.2
    Noted : T1:Incoming Water Temperature (℃)      T2:Required Chilled Water Temperature(℃)    
        
    For example, what size of chiller is required to cool 5m³ water from 25°c to 15 °c in 1 hour?
    Temperature Differential = 25℃-15℃=10℃
    Water Flow Rate = 5 m³/hour
    Cooling Capacity in KW = 5 x 10 ÷ 0.86 = 58,14 KW
    Oversize the chiller = 58.14 x 1.2 = 69.76 KW
    69.96kw cooling capacity for chiller is required.

    3.2 Power

    Different countries and regions have different standards for industrial electricity, the common power supplies are 208-230V, 380-420V,440-480V,50Hz or 60Hz, 3phase.

    Such in Philippines ,the power supply is 220V 60HZ 3PH , 380V 60HZ 3PH ,460V 60HZ 3PH;

    in Singapore and Malaysia ,the power supply is 415V 50HZ 3PH;

    in Mexico ,the power supply is 220V 60HZ 3PH;

    In USA ,the power supply is 208V 60HZ 3PH;575V 60HZ 3PH;480V 60HZ 3PH and so on

    3.3 Water Pump

    When you decide the capacity/tonnage of the chiller, we will recommend you the suitable pump in KW,which standard water pump is about 2 bar .If you need more high water pressure , please us when you inquiry.

    3.4 Refrigerant

    R22, R407C, R404A, R134A are optional choices.

    R22: good cooling effect, but R22 is considered a powerful greenhouse gas, so it’s forbidden in most countries.

    R407C: a good replacement for R22, good cooling effect.

    R404A: suitable for application that requires low temperature(below -10°c).

    R134A: a non-flammable gas used primarily as a “high-temperature” refrigerant, suitable for air-cooled chiller working at a high ambient temperature above 50℃.


    3.5 Evaporator Choose

    Air cooled screw chiller generally uses one evaporators: just is shell and tube heat exchanger.(See Above 2.2)

    Shell and tube type evaporator, which requires an additional water buffer tank to connect.

    3.6 Buffer Water Tank Capacity Choose

    Buffer tank’s capacity can be customized according to specific needs. It can buffer a larger heat load, store more chilled water .


    304 Stainless Steel Water Tank 

    4.How Choose Water Cooling Tower For Your Water Cooled Screw Chiller?

    There are three important temperature factors you need to consider when choosing a cooling tower for water cooled screw chiller: inlet hot water temperature, outlet cold water temperature, and wet bulb temperature. The hot water temperature is that which enters the tower. The cold water temperature is that which leaves the water while the wet bulb temperature refers to the prevailing temperature of the geographic region where the tower is located.

    Approach is the term used to refer to the difference between the temperatures of the water source as it enters the tower versus the temperature of the water once it has left the tower. This is a crucial determiner of the effective of the heat exchange process.

    To choose the right cooling tower, mechanical efficiency should be given priority. This refers to the amount of fan power needed to circulate ambient air within the cooling tower. The range – or the difference in temperature between hot and cold water – is also crucial as it will impact energy usage.

    so to find out how to choose a cooling water tower with sufficient cooling capacity, you should understand what circumstances require the use of a cooling tower. Please find the below water cooling tower is suitable for water cooled screw chiller :

    Cooling Capacity of Chiller                            Water Cooling Tower Capacity 


    70HP(230KW/65 Ton)                                        80 Ton


    80HP(250KW/70 Ton)                                        100 Ton


    90HP(300KW/85 Ton)                                         100 Ton


    100HP(350KW/100 Ton)                                     125 Ton


    110HP(375KW/110 Ton)                                      125 Ton


    120HP(415KW/117 Ton)                                      150 Ton


    140HP(470KW/130 Ton)                                       175 Ton


    160HP(500KW/140 Ton)                                       175 Ton


    170HP(560KW/160 Ton)                                        200 Ton


    180HP(590KW/165 Ton)                                        200 Ton


    200HP(610KW/173 Ton)                                        250 Ton


    Water Cooling tower

    5.What is the Difference Between Air Cooled Screw Chiller and an Water Cooled Screw Chiller

    Air-cooled and water-cooled screw chillers are both types of chillers used for cooling applications in various industries.
    The main difference between air cooled screw chiller and water cooled screw chiller is condenser :
    The condenser of an Air-Cooled Screw Chiller is cooled by the ambient air,which the heat generated during the cooling process is dissipated into the surrounding air;

    Water Cooled Screw Chiller with a shell and tube water-type condenser that is attached to a cooling tower and is typically used in medium and wide installations where water is available.So Water cooled screw chiller need connect with water cooling tower and water cooling pump outside , the installation is more trouble than air cooled screw chiller .
    But if your ambient temperature is very high above 50℃,we suggest you use water cooled screw chiller ,as air cooled screw chiller may consume more energy to achieve the same cooling capacity due to the limitations of air as a heat exchange medium and water cooled screw chiller uses constant water source for more stable and efficient heat dissipation,so in high ambient temperature , water cooled screw chiller is more energy-efficient and better choice for your application .


    Air Cooled Screw Chiller 


    6.Industrial Applications of Water Cooled Screw Chiller

    Water-cooled screw chillers are very popular refrigeration system that can provide steady and reliable water cooling sources for both industrial and commercial usage.
    Water cooled screw chillers are also widely used in plastic industry.food industry and Cement/ Concrete Cooling.

    6.1 Plastic Industry 

    Water-cooled screw chillers are also widely used in plastic processing and plastic industry including plastic injection molding, plastic extruders, and extrusion lines, blowing molding machines.
    The function of using an water-cooled screw chiller is to provide the cooling water flow rate for cooling the plastic mold temperature down to make sure the product quality and production efficiency.


    Water Cooled Screw Chiller For Plastic Industry  

    6.2 Food Industry 

    Water cooled chiller chillers are important in the food industry to maintain temperature control, preserve quality, support various production processes, and comply with regulations.

    Water Cooled Screw Chiller For Food Industry

    6.3 Cement /Concrete Cooling

    Cement production involves a series of chemical reactions that generate significant amounts of heat.Cement is usually mixed with water to from the material known as concrete whose temperature is to a great extent determined by the water used in the chemical combination of cement aggregates and water.

    Water Cooled Screw Chiller For Cement /Concrete Cooling

    7.Contact Us to Learn More About Our Industrial Water Cooled Screw Chiller

    Don’t delay in making the best decision for your manufacturing business and your future by increasing your production capabilities with an water cooled screw chiller. Contact us today for more information on a chiller.
    Our probessional team will help you with any questions you have on our chiller units. We look forward to hearing from you.

     Water Cooled Screw Chiller With One Screw Compressor Specification Data Sheet



    Water Cooled Screw Chiller With Two Screw Compressors Specification Data Sheet

    1.How does a chiller system work?
    Chiller has two circulation,one is process water circulation,the other is refrigerant gas circulation.Heat picked up from the process.Heat transfers to refrigerant circulation.Heat is remove to air or water.

    2.How to calculate right cooling capacity for chillers?
    One of the most frequently ask about how we can know the cooling capacity for chillers. Let’s see the below formula.
    Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-T2)/0.86
    Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)
    Oversize the chiller by 20% Ideal Size in KW = KW x 1.2
    Noted : T1:Incoming Water Temperature (℃)      T2:Required Chilled Water Temperature(℃)    
        
    For example, what size of chiller is required to cool 5m³ water from 25°c to 15 °c in 1 hour?
    Temperature Differential = 25℃-15℃=10℃
    Water Flow Rate = 5 m³/hour
    Cooling Capacity in KW = 5 x 10 ÷ 0.86 = 58,14 KW
    Oversize the chiller = 58.14 x 1.2 = 69.76 KW
    69.96kw cooling capacity for chiller is required.

    3.Types of chiller system?
    There are two types of chiller :Air Cooled Screw Chiller and Water Cooled Screw Chiller.
    Water cooled chiller needs a separated water cooling tower and water cooling pump ,if you don‘t have exsiting water cooling tower,we suggest you use air cooled chiller; But if your ambiemt temperature is very high above 55℃ ,we suggest you use water cooled chiller , as it is easier to dissipate heat for water cooled chiller with water cooling tower.

    4.Cooling capacity unit conversion?

       1 KW=860 kcal/h ; 

       1 TON=3.517 KW; 

       1 KW=3412 Btu/h;

    5.This chiller could do heat recovery?
    Yes,please kindly send us the temp and water volume per hour.

    6.Chiller maintenance?
    Step 1: Keep Tubes Clean
    Step 2: Ensure a Leak-free Unit
    Step 3: Sustain Proper Water Treatment(prevent scale, corrosion)
    Step 4: Analyze Oil and Refrigeran
    Please submit your basic information, we will contact you as soon as possible!

    *

    *

    File Name : Format: Size: Download:

Related products

  • Tel:+86 15320636029
  • Add:Fengxiang,Humen Town,Dongguan,China,
About Us77
Company Profile
Company culture
Factory Tour
Honor
Product
Industrial Chiller
Screw Chiller
Glycol Chiller
Explosion-Proof Chiller
Portable Chiller
Stationary Chiller
REQUEST QUOTE

Name

Email

Phone

Message

©2023 GuangDong TongWei Refrigeration Machinery Co., Ltd.   All rights reserved  
Web Design—Tiandixin